Testing
- Online NDT for Pipes NPS 2 (DN 50) or Larger
- Weld seam or each pipe shall be tested by Eddy current
- Bend Test for Pipes upto & including DN 50
- Bending Angle 90°
- Bending Radius 12 times to the OD of tube (no crack in body & weld)